Utensil washer
UF-M
- Software versions
- Standard programmes
- Soaking programme
- High-performance washing system with VarioPower
- Intelligent wash water filtration
- Hygiene interior
- Rinse aid dosing device
- Swing-up rack
- Tank water exchange programme
- Automatic start-up / shutdown
- Active energy management
- Touch screen and quick start button
- Stand-by mode
For an individual consultation or if you have any questions, please contact
- your local Winterhalter subsidiary
- the Winterhalter headquaters
Phone +49 7542 402-5327
E-Mail (infnxf5o@wtlylinterhalul0iter.bilbzi9z)
Utensil washer UF-M. Maximum power for uncompromising wash results.
With the Winterhalter utensil washer UF-M you gain a new member of kitchen staff that delivers the best results.
Depending on the nature and extent of soiling we developed customer-specific software versions that can be tailored to your exact needs.
Our new high performance washing system with VarioPower removes the most stubborn dirt and guarantees hygienic cleanliness throughout the entire interior of the machine.
In addition the UF Series comes with numerous product innovations that make using your utensil washer even more convenient and ergonomic.
The UF-M delivers excellent wash results and an ergonomic design in combination with maximum efficiency.
Technical data: UF-M
| UF Series according to size in [mm]: | |
| Technical Information | UF-M |
|---|---|
| Width | 775 |
| Depth closed /opened | 870 / 1295 |
| Height closed / opened | 1720 (+35 / -10) / 2000 (+35 / -10) |
| Input height / input width | 640 / 651 |
| Working height | 885 (+35 / -10) |
| Rack dimensions (inside) | 612 x 672 |
| Tank capacity [l] | 69,0 |
| Water protection class | IPX 5 |
| UF-M | ||||
| Technical Information | Unit | Standard | Energy | HighTemp |
|---|---|---|---|---|
| Theoretic capacity | [Racks/h] | 40 / 24 / 12 | 40 / 24 / 12 | 40 / 24 / 12 |
| Theoretic capacity short programme | [Racks/h] | 64 / 42 / 23 | 64 / 42 / 23 | --- |
| Rinse water volume* | [l] | 4,7 | 4,7 | 5,5 |
| Tank temperature | [°C] | 60 | 60 | 66 |
| Rinse temperature | [°C] | 85 | 85 | 85 |
| Max inlet water temperature | [°C] | 60 | 20 | 60 |
| Tank heating standard / performance | [kW] | 5 / 10 | 5 / 10 | --- / 10 |
| Boiler heating standard / performance | [kW] | 10,2 / 16,4 | 10,2 / 16,4 | --- / 16,4 |
| Total connection value | 380V / 3N~ 50/60 Hz: 8,7 / --- kW / 16 A 400V / 3N~ 50/60 Hz: 9,4 / --- kW / 16 A 400V / 3N~ 50/60 Hz: 10,0 / --- kW / 20 A 400V / 3N~ 50/60 Hz: 16,3 / 16,4 kW / 25 A 400V / 3N~ 50/60 Hz: 17,5 / 18,8 kW / 32 A 400V / 3N~ 50/60 Hz: --- / 24,1kW / 16 A 415V / 3N~ 50/60 Hz: 10,0 / --- kW / 16 A 415V / 3N~ 50/60 Hz: 10,8 / --- kW / 20 A 415V / 3N~ 50/60 Hz: 17,4 / 17,7 kW / 25 A 415V / 3N~ 50/60 Hz: 18,7 / 20,3 kW / 32 A 415V / 3N~ 50/60 Hz: --- / 25,5 kW / 40 A |
380V / 3N~ 50/60 Hz: 8,7 / --- kW / 16 A 400V / 3N~ 50/60 Hz: 9,4 / --- kW / 16 A 400V / 3N~ 50/60 Hz: 10,0 / --- kW / 20 A 400V / 3N~ 50/60 Hz: 16,3 / 16,4 kW / 25 A 400V / 3N~ 50/60 Hz: 17,5 / 18,8 kW / 32 A 400V / 3N~ 50/60 Hz: --- / 24,1kW / 16 A 415V / 3N~ 50/60 Hz: 10,0 / --- kW / 16 A 415V / 3N~ 50/60 Hz: 10,8 / --- kW / 20 A 415V / 3N~ 50/60 Hz: 17,4 / 17,7 kW / 25 A 415V / 3N~ 50/60 Hz: 18,7 / 20,3 kW / 32 A 415V / 3N~ 50/60 Hz: --- / 25,5 kW / 40 A |
400V / 3N~ 50/60 Hz: --- / 16,4 kW / 25 A 400V / 3N~ 50/60 Hz: --- / 18,8 kW / 32 A 415V / 3N~ 50/60 Hz: --- / 17,7 kW / 25 A 415V / 3N~ 50/60 Hz: --- / 20,3 kW / 32 A 415V / 3N~ 50/60 Hz: --- / 25,5 kW / 40 A |
|
The technical data provided here are based on an operation under ideal conditions. Depending on the local circumstances, individual values may vary and must be recalibrated on startup..
* Non-binding information. The actual need for rinse water can vary depending on the on-site conditions.