PT Series
Pass-Through
Dishwashers

Downloads
Personal Consultation

For an individual consultation or if you have any questions, please contact

  • your local Winterhalter subsidiary

  • the Winterhalter headquaters
    Phone +49 7542 402-5327
    E-Mqs8ail (info@wiq5or6nterhrwjealtehvnvr.biy+vyz)

PT Series pass-through dishwashers.
Brilliant, fast and efficient cleaning.

PT Series pass-through dishwashers guarantee perfect cleaning results in the shortest time thanks to their innovative features. Additionally, these machines provide maximum efficiency in the kitchen.

Depending on the wash items, available space and individual needs, a choice can be made from the machine models PT-M, PT-L, PT-XL and PT-500.

The PT Series machines offer many features and options and can be optimally adapted to your requirements.

The innovative design of the PT Series machines guarantees top performance for perfect cleaning results - brilliant, fast and efficient.

Complementary products

Water treatment | Chemicals | Racks
Product consultant
Winterhalter product consultant

Technical data: Pass-through warewashers

PT Series according to model in [mm]:
Technical Information PT-500 PT-M PT-L PT-XL Pass-through
Width 635 635 735 735 735
Height with feet 1485 / 1965 1.995 1.995 2.235 1480 / 1965
Depth 750 750 750 750 965
Slight input height 440 440 440 560 440
Tank contents [l] 35,0 35,0 35,0 35,0 28,0
Water protection class IP X5 IP X5 IP X5 IP X5 IP X3
PT-500
Technical Information Unit PT-500
Theoretic capacity [Racks/h] 15 / 30 / 60
Short programme [Racks/h] 60
Rinse water volume* [l] 2,4
Rinse temperature [°C]
Tank temperature [°C] 62
Water inlet temperature [°C] 60
Total connection value 6,4 (10,8) kW / validation [kW] 380V / 3N~:7,1 (8,3) kW / 16 A
400V / 3N~: 7,9 (9,1) kW / 16 A
400V / 3N~: 10,2 (13,2) kW / 25 A
400V / 3N~: --- (14,7) kW / 32 A
415V / 3N~: 6,9 (9,5) kW / 15 A
415V / 3N~: 8,4 (9,7) kW / 16/20 A
415V / 3N~: 10,9 (14,2) kW / 25 A
415V / 3N~: --- (15,7) kW / 32 A
200V / 3N~: 6,6 (7,1) kW / 25 A
200V / 3N~: 8,0 (8,1) kW / 32 A
230V / 3N~: 7,8 (---) kW / 25 A
230V / 3N~: 10,1 (---) kW / 32 A
230V / 3N~: --- (14,5) kW / 50 A
230V / 1N~: 6,9 (---) kW / 32 A
240V / 1N~: 5,1 (---) kW / 25 A
240V / 1N~: 6,8 (---) kW / 32 A
240V / 1N~: 8,4 (---) kW / 40 A
240V / 1N~: 10,9 (---) kW / 50 A
Dishes
Technical Information Unit Standard EnergyPlus HighTemp ClimatePlus
Theoretic capacity [Racks/h] 44 / 32 / 22 44 / 32 / 22 25 / 20 / 15 44 / 32 / 22
Short programme [Racks/h] 72 72 --- 72
Rinse water volume* [l] 2,4 2,4 3,8 2,4
Rinse temperature [°C] 85 85 85 85
Tank temperature [°C] 62 62 66 62
Water inlet temperature [°C] 60 20 60 20
Total connection value 6,4 (10,8) kW / validation [kW] 400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
380V / 3N~: 7,1 kW / 16 A
400V / 3N~: 7,9 kW / 16 A
400V / 3N~: 10,2 kW / 25 A / 32 A
415V / 3N~: 6,9 kW / 15 A
415V / 3N~: 8,4 kW / 16 A / 20 A
415V / 3N~: 10,9 kW / 25 A
230V / 3~: 7,8 kW / 25 A
230V / 3~: 10,1 kW / 32 A
Glasses
Technical Information Unit Standard EnergyPlus ClimatePlus
Theoretic capacity [Racks/h] 22 / 32 / 48 22 / 32 / 48 22 / 32 / 48
Short programme [Racks/h] 77 77 77
Rinse water volume* [l] 2,4 2,4 2,4
Rinse temperature [°C] 65 65 65
Tank temperature [°C] 62 62 62
Water inlet temperature [°C] 60 20 20
Total connection value 6,4 (10,8) kW / validation [kW] 400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
380V / 3N~: 7,1 kW / 16 A
400V / 3N~: 7,9 kW / 16 A
400V / 3N~: 10,2 kW / 25 A / 32 A
415V / 3N~: 6,9 kW / 15 A
415V / 3N~: 8,4 kW / 16 A / 20 A
415V / 3N~: 10,9 kW / 25 A
230V / 3~: 7,8 kW / 25 A
230V / 3~: 10,1 kW / 32 A
Bistro
Technical Information Unit Standard EnergyPlus ClimatePlus
Theoretic capacity [Racks/h] 28 / 32 / 40 28 / 32 / 40 28 / 32 / 40
Short programme [Racks/h] 72 72 72
Rinse water volume* [l] 2,4 2,4 2,4
Rinse temperature [°C] 85 85 85
Tank temperature [°C] 62 62 62
Water inlet temperature [°C] 60 20 20
Total connection value 6,4 (10,8) kW / validation [kW] 400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
380V / 3N~: 7,1 kW / 16 A
400V / 3N~: 7,9 kW / 16 A
400V / 3N~: 10,2 kW / 25 A / 32 A
415V / 3N~: 6,9 kW / 15 A
415V / 3N~: 8,4 kW / 16 A / 20 A
415V / 3N~: 10,9 kW / 25 A
230V / 3~: 7,8 kW / 25 A
230V / 3~: 10,1 kW / 32 A
Cutlery
Technical Information Unit Standard EnergyPlus
Theoretic capacity [Racks/h] 11 11
Short programme [Racks/h] 21 21
Rinse water volume* [l] 4,0 4,0
Rinse temperature [°C] 86 86
Tank temperature [°C] 69 69
Water inlet temperature [°C] 60 20
Total connection value 6,4 (10,8) kW / validation [kW] 400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A
400V / 3N~:
7,9 (9,1) kW / 16 A
400V / 3N~:
10,2 (13,2) kW / 25 A
400V / 3N~:
--- (14,7) kW / 32 A
230V / 1N~:
6,9 (---) kW / 32 A

The technical data provided here are based on an operation under ideal conditions. Depending on the local circumstances, individual values may vary and must be recalibrated on startup..

* Non-binding information. The actual need for rinse water can vary depending on the on-site conditions.